உட்சுரப்பியல் & நீரிழிவு ஆராய்ச்சி

Molecular characterization of microorganism at tip of catheters of all the interventional procedure done in CKD patients with or without diabetic mellitus – A study from developing country

Punit Gupta

According to the United States Renal Data System (USRDS) registry, infection is the second leading cause of death in patients with ESRD (the first is cardiovascular disease), and septicemia accounts for more than 75% of these infectious deaths1.The detailed study of microorganisms found at the tip of catheters of all interventional procedures would be helpful for proper management of these patients. as Infection is an important cause of morbidity and mortality among patients with ESRD Investigation number of male to female ratio were 1.5:1 with 82.22 % were of age group <60 years and 17.78 % were with age group >60 years. The present study showed 8.89 % were having HB >11 gm/dl & 91.11% were having HB <11 gm/dl, .The cholesterol level of <150 mg/dl were seen in 13.33 %, between 150 – 220 mg/dl were seen in 84.4 % and S, Cholesterol level > 220 mg/dl in 2%.In the present investigation thirty 8 patients were having normal thyroid profile in CKD patient and 7 patients suffered hypothyroidism. In the present work twenty four patients had IJV dialysis catheter, twelve patients had femoral. Dialysis catheter, one patient had subclavian dialysis catheter, Foley’s catheter were in fourteen patients & three vein flows were included in study. Other catheters included were three APD (Acute Peritoneal dialysis) catheter & four CAPD (Continuous Ambulatory Peritoneal Dialysis) catheters. In the present study clinically 15.5% patient had catheter related infection (CRI) in form of Fever with chills and rigors. The cholesterol level associated with catheter related infection (CRI) of <150 mg/dl, were 14.28% patient & with value of 150 – 220 mg/dl, were 85.7% patient. TLC count associated with catheter related infection (CRI), the number of patient with value more than 10.8 and the patient were 57.1% and value of less than10.8, only in 42.8% patient. The serum albumin level with catheter related infection (CRI) of value <3.5mg/dl were seen in 85.71% and value < 3.5mg/dl seen in 14.29%.Thus, the present study is an effort to cover almost all morphological characterization and biochemical changes of microorganism at the tip of catheter in CKD (Chronic kidney disease) patient. This study will provide an additional tool for management and treatment of infection in CKD (Chronic kidney disease) patient due to dialysis catheter, vein flow, Foleys catheter, APD (acute peritoneal dialysis) & CAPD (Continuous Ambulatory Peritoneal Dialysis) catheter.

மறுப்பு: இந்த சுருக்கமானது செயற்கை நுண்ணறிவு கருவிகளைப் பயன்படுத்தி மொழிபெயர்க்கப்பட்டது மற்றும் இன்னும் மதிப்பாய்வு செய்யப்படவில்லை அல்லது சரிபார்க்கப்படவில்லை